There is a newer version of the record available.

Published June 2, 2025 | Version v3
Dataset Open

Micro-climatic temperature measurements in the Finnish city of Tampere

  • 1. Finnish Meteorological Institute

Description

Contains measurement data of air temperature for the manuscript "Real-time measurements of micro-climatic temperature and relative humidity in the Finnish cities of Tampere and Helsinki" by Kühn et al. (in preparation) of 23 measurement stations in Tampere. Technical Info: NB: Update on 2.6.2025: data file Tampere_202505.dat added and file Tampere_Table1_New.txt added. The measurements were conducted at a height of 3 m in the locations listed in Tampere_Table1_New.txt during 07/2023-05/2025. Each measurement station consisted of three parts: a temperature and humidity sensor, a solar radiation shield, and an Internet of Things (IoT) device, which collected the measurement data and communicated them to a server via Long Range Wide Area Network (LoRaWAN). Temperature and relative humidity (RH) were measured by one integrated sensor, the Digital Matter I2C Temperature and Humidity Sensor [https://www.digitalmatter.com/wp-content/uploads/2020/09/I2C-Temperature-and-Humidity-Sensor-Datasheet.pdf]. Within the sensor, the temperature and RH were measured using the Silicon Labs Si7021-A20 I2C Humidity and Temperature Sensor chip. The chip is factory calibrated and has maximum operating ranges of 0% to 100% RH and -40°C to +125°C temperature. The measurement accuracy for temperature is maximum ±0.4°C if the ambient temperature is between -10°C and 85°C. The measurement accuracy of the chip is maximum ±3% RH if the ambient RH is between 0% and 80%. The Temperature and Humidity Sensor was protected by a radiation shield to minimize the influence of direct sunlight and thermal radiation on the measurements. The radiation shield (height 11.5 cm, radius 14 cm) was made of white plastic and consisted of 9 ventilated plates stacked in a cylindrical design allowing for adequate airflow while shielding the sensor from external radiation. Quality check The temperature data was quality checked using a multi-step procedure. First, values were screened based on long-term climatological daily minimum and maximum temperatures derived from 10 km × 10 km resolution gridded temperature data for the Tampere region (Aalto et al., 2016). Measurements falling clearly outside the climatological range were removed. Subsequently, remaining values were filtered based on statistical properties of the measurements, using median and median absolute deviation (MAD) over short time intervals to identify and remove outliers. A final threshold based on deviations from the local median was applied to exclude any remaining extreme values. The Local Climate Zones (LCZs) in Table 1. have been defined for each measurement station following the Global LCZ data (Demuzere 2022a, Demuzere, et al. 2022b) based on the Local Climate Zone (LCZ) Classification system by Stewart and Oke (2012). Table Of Contents: The descriptions of the measurement stations are in Tampere_Table1_New.txt. Columns 1. Station_code 2. Station_id 3. latitude 4. longitude 5. elevation above mean se alevel (m) 6. LCZ_global_point (LCZ at the grid point nearest to the measurement station) 7. LCZ_global_r200 (Mode of the LCZs within a 200-meter radius around the measurement station) The data (hourly Temperature) of each the measurements are in ASCII (tabulator as separator) files Tampere_YEAR.dat, with Celsius as Unit and missing value -999. Columns: 1. Station_code 2. Timestamp(YMDHH24) UTC 3. Mean temperature of the previous hour 4. Minimum temperature of the previous hour 5. Maximum temperature of the previous hour 6. Standard deviation of the temperature measurements during the previous hour 7. Number of measurements during the previous hour (usually 12) References: Aalto, J., Pirinen, P., & Jylhä, K. (2016). New gridded daily climatology of Finland: Permutation-based uncertainty estimates and temporal trends in climate. Journal of Geophysical Research: Atmospheres, 121(8), 3807–3823. https://doi.org/10.1002/2015JD024651 Stewart ID, Oke TR. Local Climate Zones for Urban Temperature Studies. Bull Am Meteorol Soc. 2012;93(12):1879-1900. doi:10.1175/BAMS-D-11-00019.1 Demuzere, M., Kittner, J., Martilli, A., Mills, G., Moede, C., Stewart, I. D., van Vliet, J., and Bechtel, B. (2022a): A global map of local climate zones to support earth system modelling and urban-scale environmental science, Earth Syst. Sci. Data, 14, 3835-3873, https://doi.org/10.5194/essd-14-3835-2022. Demuzere, M., Kittner, J., Martilli, A., Mills, G., Moede, C., Stewart, I. D., van Vliet, J., and Bechtel, B. (2022b): Global map of Local Climate Zones. Zenodo. https://doi.org/10.5281/zenodo.6364593.

Files

Tampere_Table1.txt

Files (17.4 MB)

Name Size Download all
Checksum: md5:c551ccbe55d8471b5d6cce37f992183a

PID: http://hdl.handle.net/11304/ab796a5b-7f25-40f6-80ad-41f7cf4c5f43
4.2 MB Download
Checksum: md5:116edd8681e13e47f6712046af8e3529

PID: http://hdl.handle.net/11304/e7cf0e85-d79a-4b17-b757-eb44316ff159
9.2 MB Download
Checksum: md5:d19da299579d1b369006bbb8761f5d83

PID: http://hdl.handle.net/11304/deaaf02e-6046-4454-aa3b-0fc2ce4c71ec
823.6 kB Download
Checksum: md5:0024571439c499bd3cb1d14e6cbe6e8c

PID: http://hdl.handle.net/11304/fe7ae3d4-8f39-47f6-a2a1-e41890a4e671
743.9 kB Download
Checksum: md5:df6b4443282d15b79a27b0faaf49fe73

PID: http://hdl.handle.net/11304/afd8ac0d-ca22-421f-865d-fe6713bae57b
818.2 kB Download
Checksum: md5:ba8bf5ffb7d9ddefef7500e7c66832ed

PID: http://hdl.handle.net/11304/12f8490c-89f0-4480-9edd-8216c044ff26
784.8 kB Download
Checksum: md5:e60c86340bd946321572e3ee160717a2

PID: http://hdl.handle.net/11304/9f1f52a5-5904-40b8-8ff5-1ec3257b52c1
807.7 kB Download
Checksum: md5:a4bcb6184619c3642a2395b9d4884b2c

PID: http://hdl.handle.net/11304/2361dbcf-74ea-4bcf-b99f-8d409320c03e
1.4 kB Preview Download
Checksum: md5:9c118e44c1f59e4ac7bea0cc1093532a

PID: http://hdl.handle.net/11304/3ee6a0c0-cb7e-40df-9815-bb213fe216f4
1.1 kB Preview Download

Additional details

Identifiers

FMI metadata

Parameter
  • Parameter name: Temperature
  • Parameter unit: Celsius
  • Parameter description: Air temperature at 3 m height in urban environment
Data levels (meter, hectoPascal, degree, sigma pressure levels, other) in vertical direction(+/-) for example 1500 m or 850 hPa
  • Level: 3 m
Topic category
climatologyMeteorologyAtmosphere

Temporal Coverage

Ranges:

Start date: 2023-07-10
End date: 2025-05-31